220/440 Volt, 3 Phase
Minimal backlash in feed screw and nut
Removed table and spindle assembly, cleaned all way surfaces
Cleaned and flushed lubrication system to ways
Re-aligned head stock and tail stock to proper center heights
Table and spindle slide ways were re-scraped
Rebuilt hydraulic pump
Cleaned, Paint and Cycle
Runs and SOunds like New
All Feeds and Speeds are functional